Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
1.
CorSalud ; 12(3): 247-253, jul.-set. 2020. tab, graf
Article in Spanish | LILACS | ID: biblio-1154029

ABSTRACT

RESUMEN Introducción: Existen algunos estudios que relacionan parámetros de la onda P con diferentes tiempos de conducción auricular, pero no se han realizado teniendo en cuenta a cada derivación del electrocardiograma. Objetivo: Determinar la duración de la onda P (Pdur) en las 12 derivaciones y relacionarlas con el tiempo de conducción interauricular. Método: Estudio de corte transversal en 153 pacientes adultos con diagnóstico confirmado de taquicardia por reentrada intranodal (TRIN) o vías accesorias mediante estudio electrofisiológico invasivo. Resultados: Al comparar la Pdur entre sustratos arrítmicos por cada derivación, no existieron diferencias significativas, excepto en V6. En las derivaciones DII, DIII, aVR, aVF, V1 y de V3-V6 la Pdur se correlacionó con el tiempo de conducción interauricular en ambos sustratos arrítmicos. En el análisis multivariado, la Pdur constituyó un predictor independiente de tiempos de conducción interauricular ≥ 95 percentil, en las derivaciones de cara inferior y en V3, V5 y V6. Se observaron altos valores del área bajo la curva de la Característica Operativa del Receptor en las derivaciones DII (0,950; p<0,001), DIII (0,850; p<0,001) y V5 (0,891; p<0,001). Conclusiones: No existen diferencias por derivación en la Pdur al comparar casos con TRIN y vías accesorias, excepto en V6. La mayoría de las derivaciones se correlacionaron con el tiempo de conducción interauricular. La Pdur fue un predictor independiente de tiempos de conducción interauricular ≥ 95 percentil. La derivación DII presenta la mayor capacidad discriminativa para encontrar valores prolongados del tiempo de conducción interauricular.


ABSTRACT Introduction: Although some studies relate P wave parameters to different atrial conduction times, they do not consider each electrocardiogram lead separately. Objective: To determine the duration of P wave (Pdur) in the 12 leads of the electrocardiogram and relate it to the interatrial conduction time. Method: We conducted a cross-sectional study in 153 adult patients with confirmed diagnosis of atrioventricular nodal reentry tachycardia (AVNRT) or accessory pathways by invasive electrophysiological study. Results: When comparing the Pdur between arrhythmic substrates by each lead, no significant differences were found, except for V6. In leads II, III, aVR, aVF, V1 and V3-V6, Pdur was correlated with the interatrial conduction time in both arrhythmic substrates. In our multivariate analysis, the Pdur was an independent predictor of interatrial conduction times ≥ 95 percentile in inferior wall leads and in V3, V5 and V6. High values of the area under the receiver operating characteristic curve were observed in II (0.950; p<0.001), III (0.850; p<0.001) and V5 (0.891; p<0.001) leads. Conclusions: The Pdur showed no difference by leads when comparing cases with AVNRT and accessory pathways, except for V6. Most of the leads were correlated with the interatrial conduction time; Pdur was an independent predictor of interatrial conduction times ≥ 95 percentile. Lead II has the greatest discriminatory ability to find prolonged values of interatrial conduction time.


Subject(s)
Tachycardia , Electrophysiologic Techniques, Cardiac , Electrocardiography , Accessory Atrioventricular Bundle
2.
Arch. cardiol. Méx ; 83(3): 185-188, jul.-sept. 2013. ilus
Article in Spanish | LILACS | ID: lil-703015

ABSTRACT

La complejidad anatómica y la variabilidad en el sistema de conducción en la transposición congénita corregida de los grandes vasos plantean intervenciones con el uso de recursos tecnológicos que faciliten un desenlace favorable. Describimos un caso de ablación de taquicardia por reentrada intranodal en donde el mapeo no fluoroscópico facilitó una intervención compleja.


The anatomy in congenital corrected transposition of the great arteries is complex and the conduction system may experience large degrees of variation. Invasive procedures should be done with the use of the highest possible technological sources to warrant success. We describe here, a patient with recurrent atrioventricular node reentry tachycardia where non-fluoroscopic navigation system helped in a complex ablation.


Subject(s)
Female , Humans , Middle Aged , Cardiac Imaging Techniques , Catheter Ablation , Imaging, Three-Dimensional , Tachycardia, Atrioventricular Nodal Reentry/surgery , Fluoroscopy , Recurrence , Transposition of Great Vessels/surgery
SELECTION OF CITATIONS
SEARCH DETAIL